Product Details:
|
PCS: | 1 Set | 1380kWh Battery Storage System: | 1 Set |
---|---|---|---|
Convergence Cabinet: | 1 Set | External DC Cable: | 1 Set |
Fire Fighting System: | 1 Set | Air Conditioning System: | 1 Set |
Lighting System: | 1 Set | ||
High Light: | ESS Energy Storage System,BMS Energy Storage System |
Working conditions of the battery system
1 ) Ambient temperature of battery test system:
Charge: 0C~60C;
Discharge:-20C~60C;
2) External environment temperature difference:≤5 C;
3) Environment humidity of battery system:10%~90%RH;
4) It is recommended to maintain more than 20% SOC in operation, and avoid full charge and full discharge.
5) When the battery system is not in use for a short period of time, it is required to maintain more than 60% SOC and store in a dry, clean and well-ventilated warehouse at 5 C ~45 C . Conduct charge/discharge test and monitor battery status at least once a month, including total battery voltage, battery cabinet voltage, temperature, voltage difference, temperature difference, insulation resistance, SOC etc.; if any problem is found, after-sales maintenance personnel should be notified in time for troubleshooting.
6) In the process of battery loading, it is required to move gently and prevent dropping, tumbling and impacting.
7) Do not store upside down or lying down; do not expose the battery pack to sunlight, rain or water for a long period of time
8) In the process of operation, daily maintenance and inspection must be done strictly in accordance with the requirements.
9) Ensure that the battery system is operated or stored away from flammable and explosive materials and a high-temperature environment
10) It is strictly prohibited to run a battery system by force in the status of a short circuit, overcharge, or high-temperature alarm.
11 ) It is strictly forbidden for users to disassemble the battery system without permission.
Description of Product
No. | Configuration | Quantity | Unit | Remarks |
1 | PCS | 1 | piece | 500KW |
2 |
1380kWh Energy storage battery cabinet |
1 |
unit | / |
3 | Combining manifolds | 1 | unit | / |
4 | External DC cable | 1 | set | / |
5 | Firefighting system | 1 | Set | / |
6 |
Air conditioning system |
1 |
pc |
Vehicle air conditioning 24V Auxiliary power 2A/DC 400V~800V Start-up current ≤17A Cooling capacity 13.3KW |
7 | Lighting system | 1 | set | Waterproof and explosion-proof LED light |
Environmental Requirements
No. | Specification | Requirements | Remark |
Ambient temperature |
-20C~60C |
-20 C: can start and work continuously 0C~60C: perform fully above 60C: working stop |
|
Storage temperature | 5C~45C | Air temperature changes less than 1C/min | |
Relative Humidity |
0~95% | No condensation | |
Environmental grade | Pollution level 4 | ||
Altitude | 0~2000m | ||
Atmospheric pressure | 79 kPa~106 kPa | ||
Assembly Method |
Vehicle load | ||
Transportation | Vehicle, train, ship |
Specification of Battery
Battery cell |
1 | Cell chemistry | LiFePO4 |
2 | Voltage | 3.2V | |
3 | Capacity | 500Ah (25C, 100% DOD ,0.5C) | |
4 | Dimension | 430×790×17mm | |
5 | Weight | 10±0.2kg | |
6 | Life Cycles | ≥4000 cycles (25C,80%DOD,1/3C) | |
Battery Technical Standards |
7 |
Conforming Standards |
GB/T31484-2015 , GB/T31485-2015 , GB/T31486-2015,QC/T743-2006 |
Specification of Battery Box
Specification |
1 |
Nominal Capacity |
500Ah |
|
2 | Nominal Voltage | 76.8V | ||
3 |
Nominal Capacity |
38.4kWh | ||
4 |
Series-parallel Connection |
1P24S |
||
5 | Cycle Life | 3500 Cycle (20%~95% SOC,20±5C) | ||
6 |
Ambient Temperature |
Charge Temp. | 0 C~45C | |
Discharge Temp. | -10C~60C | |||
7 | Working Voltage | 60V~87.6V | ||
8 | Charge Current | 250A | ||
9 |
Rated Discharge Current |
250A |
||
10 | Cooling Method | Forced Air Cooling | ||
11 | Dimension | 836mm ×568.5mm ×455mm | ||
12 | Weight | Approx. 300kg |
Specification of Cabinet
Specification |
1 |
Nominal Capacity |
500Ah*4 |
|
2 |
Nominal Voltage |
691.2V |
||
3 |
Nominal Capacity |
1380kwh | ||
4 | Cycle life | 3500 cycles (20%~95% SOC,20±5C) | ||
5 |
Ambient Temperature | Charge Temp. | 0C~45C | |
Discharge Temp. | -10 C~60C | |||
6 |
Working Voltage |
547.5V~788.4V | ||
7 |
Charge current |
250A |
||
8 |
Nominal discharge current |
250A |
||
9 |
Series-parallel Connection |
1P24S-9S*4 |
||
10 | Dimensions | 4490*655*2100MM | ||
11 | Weight | Approx. 3T |
Contact Person: Lisa Lin